Home › Equipment › Buying a reach-in refrigerator in Florida
Buying a reach-in refrigerator in Florida
- Pick what you need and give your kitchen's ZIP code.
- Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
- You talk with them and decide. You hire and pay the company directly.
Facts checked 2026-11-15.
Every food kitchen needs cold storage within arm's length of the line. A reach-in refrigerator is the upright cabinet that does the job. Buyers choose between doors, sections and temperature range, and they also have to meet the Florida rules on holding temperature.
Kinds, sizes and fuel
A reach-in is an upright cabinet that holds food cold, with solid, glass or half doors. Traulsen lists one, two and three section units and pass-thru models. Hoshizaki lists one, two or three sections, full or half doors, refrigerator, freezer or dual-temperature units, and undercounter models.
Model pages give the details that matter for the order. A Beverage-Air two-door page lists R290 refrigerant, ENERGY STAR certification and a seven-year warranty on parts, labor and compressor. Its page lists both a 30.76 cubic foot spec and a one-door spec row, so confirm the model before you rely on the number.
Reach-ins run on electricity, so the fuel question is voltage, amps and plug type.
Makers of reach-in refrigerators include Beverage-Air, True, Traulsen and Hoshizaki.
What Florida checks
Florida applies the 2017 FDA Food Code, and Rule 61C-4.010 brings in Chapter 4 on equipment. NSF/ANSI 7 covers commercial refrigerators and storage freezers, and NSF's certified listings show reach-in, undercounter and prep-table headings. The Food Code deems equipment certified by an ANSI-accredited program to meet its design rules (4-205.10).
The Food Code's core demand is temperature. Cold food that needs time and temperature control is held at 41 F or below (3-501.16), and the equipment must have enough cooling capacity to do it (4-301.11). A cold holding unit for such food needs a built-in temperature measuring device placed in the warmest part of the unit (4-204.112). DBPR's packet repeats the point: refrigeration at 41 F or colder, with thermometers.
For plan review, the equipment is labeled on the scaled floor plan. Read the opening a restaurant guide for the wider order of steps, from plan review to the licensing inspection.
UL's guide lists UL 471 for commercial refrigerators and freezers. Ask the seller which listing marks the unit carries.
The sources we read tie no hood requirement to refrigeration.
Get prices for this item. One request, and you pick how many sellers quote it.
Get quotesEnergy use and rebates
Two energy rules apply here. The US Department of Energy sets maximum daily kilowatt-hours for self-contained commercial refrigerators, freezers and refrigerator-freezers with solid or transparent doors, in 10 CFR 431.66. The revised limits apply to units made from March 27, 2017. The same section says its standards do not apply to salad bars, buffet tables, chef bases or griddle stands.
ENERGY STAR goes further for solid, transparent and mixed door units, with maximum kilowatt-hours a day by volume and door type under Version 4.0. Prep tables, chef bases, open-air units and remote condensing units are not eligible.
In November 2026 we read the FPL and Tampa Electric business pages and saw no rebate aimed at kitchen equipment. The ENERGY STAR Rebate Finder covers rebates by zip code, so use it, then ask your utility.
What to ask a seller
- How many doors and sections does it have, and how many cubic feet does it hold?
- What are the voltage, amps, plug type and refrigerant?
- Does it carry the NSF/ANSI 7 mark and an electrical listing, and is it ENERGY STAR certified?
- Does it have a built-in thermometer you can see from outside?
- What are the compressor and parts warranty terms? Traulsen lists six years on parts and labor and seven on the compressor.
- What rear and side clearances does the spec sheet call for?
The sellers who receive a reach-in request are the one to five you choose.
Other kitchen equipment
Questions
What temperature must a commercial reach-in refrigerator hold in Florida?
A commercial reach-in refrigerator must hold time and temperature controlled food at 41 F or below, under the Food Code's section 3-501.16. DBPR also expects thermometers on refrigeration.
Does a reach-in refrigerator need to be NSF certified?
A reach-in refrigerator is covered by NSF/ANSI 7, and the Food Code treats ANSI-certified equipment as meeting its design rules. The NSF mark on the exact model is the common proof.
Is a commercial reach-in refrigerator ENERGY STAR certified?
A commercial reach-in refrigerator can be ENERGY STAR certified if it has solid, transparent or mixed doors and meets the daily kilowatt-hour limit. Prep tables and chef bases are excluded.
Does a commercial refrigerator need a thermometer in Florida?
A commercial refrigerator holding food that needs temperature control must have a temperature measuring device, per the Food Code's 4-204.112. The sensor goes in the warmest part of the unit.
Sources
- FDA 2017 Food Code
- Rule 61C-4.010, Florida Administrative Code
- DBPR plan review packet (HR-7030)
- NSF certified food equipment listings, NSF/ANSI 7
- UL, Commercial Cooking Marking and Application Guide
- 10 CFR 431.66, commercial refrigeration standards
- ENERGY STAR, commercial refrigerators and freezers
- ENERGY STAR Rebate Finder
- Florida Power & Light business programs
- Tampa Electric business
- Beverage-Air two-door reach-in
- Traulsen G Series
- Hoshizaki refrigeration